  • Selected electronic components: The current signal isolator adopts high-quality electronic components with high precision and can be used for a long time.
  • Anti-aging: It has good resistance to high and low temperature, excellent insulation, moisture-proof, anti-leakage, anti-vibration, anti-aging, anti-corona, etc.
  • Features: The internal use of high-efficiency magnetic isolation technology, the input, output, and power supply are isolated from each other, with high precision, high linearity, and low temperature drift.
  • Strong practicability: Provide isolated power distribution for field transmitters, and at the same time isolate and transmit the current signal generated by the transmitter from the field to the control room, PLC, DCS and other input terminal interface current sources. 35mm standard rails are installed as DC signal isolators Brings strong versatility and is very practical.
  • Anti-interference: Support input/output/power supply/shell isolation, strong anti-interference ability and high reliability.


Specification:


Item Type: DC Signal Isolator
Material: ABS
Model: GLG
Channel: 1 in 1 out
PWR (15-, 16+): 24V DC
Input: 0-5V
Distribution Voltage: DC24V
2-Wire System: (9-, 13+)
3-Wire System: (9+, 10-, 13+)
Power Supply: (9+,10-)
Output:
Channel 1 (1+, 2-): 0-10V
Output Current: Load≤500Ω
Output Voltage: Load≥10KΩ
Accuracy: 0.1% FS
Working Temperature Range: -20~+55℃
Electromagnetic Compatibility: Comply with GB/T 18268 (1EC61326-1)
Applicable Field Equipment: Two-wire, three-wire transmitter, current source



Package List:

1 x DC Signal Isolator


Note:

1. The installation location must not have strong vibration, and the intensity of electromagnetic interference from the signal terminal, power terminal and space exceeding the third type of industrial field electromagnetic interference in the IEC61000‑4 series.