Your cart is empty.Stefano
2025-09-01 19:31:54
These are cheap thermocouples. Great value for money. Found that they are about 3-5 degrees colder than other probes I have, and read 27 degrees in ice water. Easy fix for microcontroller based projects.
Carl Wittig
2025-08-31 16:04:50
10 Pack Of Thermocouples Are Ok Item At Best. Per Packaging, Only Good Up To 400 Degrees Farenheight NOT 400 Degrees Celsius Per The Add. At Least 1 Out Of The 10 Had A Broken Junction.Not Stated, But Per Calipers Measure 29 Gauge Wire, With Teflon Jacket.Individual Wires Are Red And White.. That Is The USA Color Code For A Type J Thermocouple, But Internationally, Some Countries use This Color Code. Simple Boiling Pot Of Water Showed Close To 212Deg F. Yellow Connectors Are Pretty Good, But With Sloppy Termination Around The Screws.
Dennis
2025-07-27 13:08:12
Bought these thermocouples for my fluke meter work is designed no issues will buy again if needed
gjump
2025-07-26 13:58:45
A great replacement for High and Low temperature. Connector is marked clearly for positive and negative.
DaveyB
2025-07-15 13:47:22
For the money, these are good TCs. The wire is of a thin gauge (which is what I needed) and the junctions themselves are excellent. The mini plugs, however, are of the poorest quality I have seen. This is easily remedied with new mini connectors and they are still a great value.
King Slugopotamus
2025-07-09 15:32:03
Bought these for a project, and they work fine - seem to be exactly what they claim to be, performance-wise.HOWEVER - be really aware that they are absolutely *not* built using a standard K type thermocouple color code.If you use the yellow connectors and go by the polarity markings molded in them, you're golden.But if your application requires a direct connection to a meter or PLC... yeah no, go by which wire is connected to which terminal on the yellow plug to save yourself a ton of grief...
Ray West
2025-06-08 13:41:32
After purchasing the set of quantity 20 K Thermocouples, I found the root cause of intermittent meter display using the Low Ohm setting if using manual DMM. Ohms is typically 14-15 at room temp.1. Most common cause I found, was 7 out of the 20 had a stripped screw inside the plug (have to remove the 3 case screws). 6 out of the 7 were the positive (+) screw post would not tighten. 1 was on the Negative terminal post.2. 2 of them had terminal screw(s) not tighten.I took all 20 units apart as I was shortening the leads on some of them. Be sure to have a small magnetic screwdriver for reassembly...You will need one! Note: The top 3 Case screws do not have to be removed from the Yellow 1/2 case....just backed out a ways to remove.
Martial Burguieres
2025-02-13 11:49:02
Used for testing exotherm on resin samples. So, they can only be used once as the resin is very strong once cured. They are accuarate and priced to where I don’t care about consuming them.
Jacqueline
2024-11-25 16:57:00
De los 10 cables, 1 no estaba soldado y otro estaba mal soldado, por lo que tuve que hacer la reparación previo a su uso.Además, uno dejo de funcionar mientras se estaba utilizando.Los demás funcionan correctamente.