Shopping Cart

Your cart is empty.

Your cart is empty.

7?30V 0?30A DC Current Detection Sensing Module Board Overcurrent Relay Module Current Sensor Module

Free shipping on orders over $29.99

$18.84

$ 7 .99 $7.99

In Stock
  • User-Controlled: This module detects DC current and controls the relay's based on user-defined limit current settings. This allows for customized usage tailored to your specific needs.
  • Accuracy and Range: Capable of detecting a DC range from 0-30A with precision up to 0.01A, offering you and accurate readings.
  • Error Calibration Function: Equipped with an error calibration function to ensure accurate and dependable performance.
  • Power Efficient: The module has an option to disable the LED display, reducing power consumption for energy-efficient usage.
  • It can be utilized to limit current in the circuit, protecting your electrical equipment from damage due to excessive current



Product Description

GS10835-1

7?30V 0?30A DC Current Detection Sensing Module Board Overcurrent Protection Relay Module Current Sensor Module

YT

Setting description:

Power on, display the measured current; (if the measured current terminal is none, the LED digits will pulse)

Press K1 for the second time (for over 1s to prevent misoperation), the screen shows: P11, k2 adjusts mode, K3 adjusts function

Package list:

1 * DC Current Detection Module​

1

GS10835-2

GS10835-3

1

GS10835-2

GS10835-3

Specification:

Model: YYI-4

Supply voltage: DC 7-30V

Detection range: DC 0-30A

Accuracy: 0.01A (10mA)

Standby current: About 20mA

Weight: Approx. 86g/3.0oz

Function description:

P-11: When the measured current > I1 (low limit current), the relay closed; When the measured current

P-12: When the measured current > I1, the relay closes; Maintain the state until the circuit board power off;

P-21: When the measured current > I2 (high limit current), the relay closes; When the measured current

P-22: When the measured current > I2, the relay closes; Maintain the state until the circuit board power off;

P-31: When measured < I1, the relay closes; When the current > I2, the relay opens;

P-32: When the measured current < I1, the relay closes; Maintain the state until the circuit board power off;

P-41: When the measured current is between I1 and I2, the relay closes, opens in other cases;

P-42: When the measured current is between I1 and I2, the relay closes; Maintain the state until the circuit board power off;

P-51: When the measured current I2, the relay closes, opens in other cases;

P-52: When the measured current < I1 or > I2, the relay closes; Maintain the state until the circuit board power off.