Shopping Cart

Your cart is empty.

Your cart is empty.

Elitech Digital Temperature Humidity Data Logger Pharmacy DDL with Calibration Certificate to auditor, Refrigerator Thermometer Vaccine Fridge Temperature Monitor Max Min Value GSP-6

Free shipping on orders over $29.99

$38.99

$ 18 .99 $18.99

In Stock

1.Color:Gsp-6 100000points


2.:Gsp-6 Series


3.:10


About this item

  • Designed to meet CDC/VFC requirements and FDA 21 CFR Part 11 compliance.
  • Why Elitech - Focus on the research and development of life science and food cold chain full-process data visualization products. Applied in vaccines, nucleic acid detection, IVD, blood products, hospital pharmacies, CDC, cold chain logistics, warehouse management and other fields
  • Easy to install - Built-in magnet, can be directly adsorbed refrigerator fixed. The benefit of the separable probe is that the probe no longer needs to be precooling after each time the device is moved
  • High precision probe - Accurately sense small changes in temperature. With a wide measurement range temperature -40℉ to 185℉, humidity 10%~99%RH
  • Battery & USB Dual Power - Power on USB Port when battery is flat
  • Value Visibility - Current temperature and MAX MIN value can be obtained from the large LCD screen
  • Parameter Settable - Temperature unit switch, Alarm Range, Logging Interval. For more function, please download Elitechlog software
  • Single-button - Easy to start, stop and switch between different interfaces
  • Audio and Visual Alerts - Audible and Visual Alarm help you find the abnormal cases in time
  • What You Get - Data Logger, USB Cable, 2 External Sensors, Calibration Certificate, User Manual, Elitech 12-months Warranty & 24/7 Customer Support Access via Email and Phone



Product Description

Designed for Vaccine Storage

GSP-6

Selectable Sensor

gsp-6-sensor

Technical Specifications

Temp Range -40°C~+85°C (-40°F~185°F)
Temp Accuracy ±0.5°C/±0.9°F (-20°C~+40°C), +1°C/±1.8°F (others)
Humi Range 10%RH~99%RH
Humi Accuracy ±3%RH (25°C, 20%RH~80%RH), ±5%RH (others)
Resolution 0.1°C/°F; 0.1%RH
Memory Maximum Maximum 16,000 points
Logging Interval 10 seconds to 24 hours
Data Interface Micro USB
Software ElitechLog, for macOS & Windows system
Report Format PDF/EXCEL/TXT*via ElitechLog software (TXT for Windows ONLY.)
Power supply Single-use 3.6V ER14505 lithium battery; Or powered via USB
Battery life Two years at room temperature with 15 minutes record interval and buzzer alarm disabled.
Certification EN12830, CE, RoHS
Dimensions 118x61.5x19 mm
Logging Mode Stop when full; Circular logging
Alarm Configuration Buzzer; LCD display
  • 1. Install Elitechlog software. Insert the device into a computer USB port.

    2. Click ""set parameter"" and then click ""save parameter"" to exit.

    3. Press and hold the left button for more than 4 seconds to start recording.

  • Click "Quick Reset" to reset the original parameters settings. Disconnect the device from your computer to start using it again.

    Note: Please read and save the historical data before parameter settings or the data will be clear.

  • The recorded data can be cleared by the data management software by setting parameters.

  • 1. Plug the data logger to a computer USB port, the icon will light in the screenafter connection.The green LED indicator will light at the same time.

    2. Open the data management software, the data logger will connectautomatically and upload data.

  • Please download and install the free ElitechLog software (macOS and Windows) from Elitech US: elitechus.com. Search 'Elitechlog' in the APP store to obtain MAC software.


Tom Tomato
2025-08-26 15:32:34
We have been having problems with excess water build up and overflow in the drip pan of our Sub-Zero refrigerator. The heater that is supposed to evaporate the water doesn't seem to be working properly despite multiple repairs. But how do I prove it isn't working correctly?Enter the Elitech Data Logger GSP-6. I set it to record temperature at 1 minute intervals. I now have a clear graph of a week's worth of data showing how the temperature of the water in the drip pan cycles between 72 and 82 degrees every few hours, which is not enough to evaporate the water. A senior service tech is now scheduled, based on this data. Finger crossed.This device is a quarter the price of other brands of data loggers that I looked at. The software is perfectly serviceable (I'm on a Mac). I was a little unsure how to set some things up, but trial and error and poking around on the desktop app were enough, along with other users' comments in reviews. There are a lot of features in the "Parameters" tab so you can really customize how this thing works. It is super easy to unplug the unit from the sensor cable and plug it in to my Mac via USB to download the data. The re-connect the unit to the sensor cable to continue collecting more data.Some people complain that the English translation of the manual isn't that great. It's not, but you know what - who cares? At least Elitech does provide written documentation, unlike many companies today who give you a scrap of paper with a few pictograms to scratch your head to. I struggled with some of the wording, like "to start press the button until the light flashes out." What is flashes out? But once I figured out what they meant by "flashes out" I started used that expression myself.Altogether, this is a very reasonably priced product that is a must-have if you need to monitor temperature and want to download a graph and data of the results. Be prepared to put on your thinking cap to figure out the software, but it is worth a bit of effort. I haven't used the humidity sensor yet but it could be handy some day. For now I'm keeping the humidity sensor in the surprisingly nice box that the data logger is packaged in. The box is a high quality you don't see much of today and even has a nice magnetic closing flap.
DCI
2025-07-31 17:19:44
This is really a great tool for the price. I used it to log the temps. for a new "smart pump" that I installed for a client. Set it to log every minute and was able to discover an issue with cold water moving backwards thru the pump. Then I moved the sensor and discovered that the tank outlet temp. was set too high through the tempering valve and got these fixed before they became an issue. One reviewer said that the temperature on theirs was way off, mine was within 0.7 degrees (compared to a certified calibrated thermometer), the software allows you to add or subtract to adjust the calibration so that is a non issue. Other loggers that I looked at were either way more expensive or didn't have the features. This is a great tool for HVAC or plumbing trades to see how your setup is working without having to sit there and watch the unit all day.The parameter screen lets you set up everything exactly how you want it, turn it on and off in the field and download to a graph for simple view of what's going on, save as a JPEG for future reference. Temp. or humidity can be used separately or together. You do need to download it to a computer to view the data though.
Customer
2025-07-20 11:11:46
I use this for storing and packing out refrigerated COVID and other vaccines for my mobile clinic. It passes state standards and functions well but you HAVE to leave it running. Comparing this to 2 other loggers, one state supplied and the other installed on the fridge, it's pretty accurate. Had a hiccup after about a month where the temperature suddenly stopped working. I worked with the manufacturer and they replaced the whole unit. Turned out it was the cord for the glycol bottle. I was able to replace the battery with a regular AA battery when troubleshooting the issue before replacement and it was fine. However the battery has never died and I leave it running all the time. The software is a bit clunky but I really didn't expect it to be sleek and easy for the money. 🤷🏾‍♀️ You get what you pay for.
Patrick Walsh
2025-07-17 18:20:59
Updated review: Nothing but trouble. Disclaimer, I am having to mail this logger back and forth to the place of instrumentation and coordinate with someone else to set it up. However, the logger has not functioned all three times I have mailed it back and forth. Wasting time and money. The first time, it didn't trigger properly. The second time, it triggered, and then I we tried to stop it so we could re-start it the next day. Apparently that is not possible without plugging the thing into the software again (that is NOWHERE in the documentation), so had to send it back again to reset. The final time, everything seemed to trigger properly, the logger started counting up, but at the end of the logging period it just wiped all of the data and will no longer connect to a computer. Garbage. They need better software engineering on this thing.Original review: What a great little tool! I am only using it for temperature measurement of graywater, so I can't comment on the humidity function. Super easy to set up and configure in the free software. Really nice software that has some nice post-processing automatically done. The auto graphing function is really nice. Great little device! Only wish it had a bit more internal memory, as I want to log every 10 seconds and it maxes out at 1D 20Hr of time. That's a minor niggle though. Highly recommend.
luiggi
2025-06-19 16:12:07
Excelente
JetMech727
2025-05-24 13:58:07
Seems to work well. Very poor operating instruction though. Can't figure out how to change form C to F.
david Arturo Zamarripa Ocampo
2025-04-26 17:29:36
Una de las 2 sondas no funciona, o el aparato en si.Intente hacer reset con el software, hice pruebas cambiando la configuracion, y nada, debe estar defectuoso... ahora viene el tener que hacer el envio para la devolverlo.
Atrik
2025-04-12 14:36:33
Unreliable readings. The readings are way off compared to two other monitors. When placed side by side about 2 inches apart, both probs gave different results. The readings were off by 2-3 degrees. This raises questions about the device's accuracy and reliability.
Lorenzo
2025-03-08 18:36:57
Consegna puntualeFacile da impostare e consultareSperiamo che sia affidabile nel tempo!
اسامه
2024-12-22 11:10:13
ممتاز و يؤدي الغرض منه بكل كفاءة
Leonardo Woo
2024-11-28 18:44:37
Cumple con su función muy bien, sus valores son muy precisos y coherentes. Lo utilizo para investigacion meteorológica.
Recommended Products

$610.00

$ 99 .00 $99.00

4.9
Select Option

$499.00

$ 99 .00 $99.00

4.3
Select Option