Your cart is empty.
Your cart is empty.Christine
2025-06-24 13:36:29
easy to use, no leaking
Kyle suarez
2025-05-28 16:33:18
I was skeptical about these after reading some sketchy reviews but after using these for 410A refrigerant (350+psi) for atleast 2 weeks now I have had no issues. I use one every single time I put my "gauges" (bluetooth psi sensors) on just incase I need to add refrigerant and they have held up great and charging with them works great too! You just need a refrigerant hose with a lowloss ball valve so you can open and close one end the hose for easy charging without a Guage manifold. These do have shraders pre-installed FYI and the female end has a shrader depressor. A+!
Luis Martin Martinez
2025-05-12 18:46:56
Good
What'sUp
2025-05-10 17:02:44
The only thing that I wish were different about these is that they come with cheaper green seals instead of the higher quality rubber seals that most of your high quality hvac fittings/tools have. I could not deduct any stars however because these are definitely worth the price when you compare them to the overpriced name brand refrigeration tools! It's ridiculous that anything with the well known names dealing with hvac has to be so outrageously overpriced!! I will eventually change the seals out with the higher quaility rubber seals as needed in the future! As for now I feel great getting my money's worth on something that most people get taken to the cleaners for in this economy! Would definitely buy again!
The Dude
2025-04-14 13:53:51
They don't leak and they do their job, not much more I can say about em.
Mary
2025-03-27 13:44:15
If you look at the Amazon listing for this item you'll note that the body to nipple connections have sealant perhaps a solder joint??? If you look at the photo of the ones I received there, is no sealant, probably a press fit. I bought these particular T's as I wanted to ensure a good joint seal but now I don't know. I'm going to test the fittings and will update this review later. Just be aware that they are selling fittings not quite what is advertized:(
Customer
2024-12-21 12:14:14
This item leaked at the non connect braze joint.
Charles G.
2024-11-17 11:50:53
Had to replace a high pressure switch on an HVAC system. This allowed me to abandon the original one that failed to add new protection in another access location without recovering and recharging the system which saved a lot of time and effort at work. The tee has another available access port to check pressures when needed.