Shopping Cart

Your cart is empty.

Your cart is empty.

SIEMENS ECINSGB14 Insulated Ground Bar with 14 Terminal Positions

Free shipping on orders over $29.99

$32.61

$ 14 .99 $14.99

In Stock

About this item

  • 14 terminal openings
  • Each terminal opening accepts No.14-4 CU/AL conductors
  • Insulated Ground Bar


Insulated ground bars are intended for use when an isolated neutral/ground is required. The non-metallic base allows for isolation from any metal enclosure that the ground bar is mounted on. Applications range from expansion of the neutral system in a load center to various OEM applications.


William A. Nolan
2025-08-22 10:17:00
I had to get several of these devices in different sizes, because the national electrical code changed and most places use it as the basis for their local codes. In essence, the code now says that neutrals and grounds must be electrically isolated in subpanels. In the main panel they still connect to the same bar. I am doing some work that requires inspection, and so I have to bring everything up to code. It happens that I have several subpanels with varying numbers of connectors, so I needed a bunch of these. It works fine. Put it in the box and move all the neutrals to the new, isolated bar. As usual, if you don't have the knowledge and experience to do this safely, hire a professional!
Paul R. Haller
2025-07-22 12:59:37
I used this as a stand alone additional neutral buss in a sub panel. As you know, in sub panels the neutral and grounds are supposed to be electrically separated. If you double up breakers in their spaces, sometimes there are not enough neutral spaces provided in the box for the additional neutral wires added. This allows you to mount the additional buss directly to the sub box because it’s insulated and doesn’t connect electrically to ground and isolates the neutral. I just run a solid #4 copper wire from the provided neutral buss to this new stand alone and isolated from ground neutral buss and you have an additional 9 spaces for neutral circuit wires.
alm
2025-06-25 18:55:16
Perfect for what I needed
Matthew H Robichaud
2025-06-23 16:44:45
had a old sub panel with a bonded neutral bar, this one did the trick
Chill Frog
2025-06-18 15:30:36
Feet were upsidedown, missing 1 mounting screw. Plastic feet shattered removing nut and screw. Zero stars if I could
Mac
2025-06-12 17:03:51
If you need an insulated neutral bar to keep grounds separate, like for a subpanel in the same building, this is the one to get. Even included an insulated pad to go underneath.
MissingNoFingers
2025-06-11 14:48:32
Works well. I actually cut all of these in half to use as two smaller bus bars for a project and worked out nicely.
Maks
2025-04-15 16:50:48
Doesn’t fit Siemens electrical panel. They should include a list of models that part will fit.
Ernesto
2025-04-07 18:17:36
Justo lo que necesitaba, la tener la base de plástico no hay problemas por la aislación.
Jeffrey Bowman
2025-03-10 20:52:11
Works as described. Used to combine neutral wires at a junction box and run a 4 AWG to the panel through conduit.
Miguel Angel
2025-03-07 15:47:37
De fácil instalación pero las instrucciones vienen en inglés. Se ve un producto de buena calidad. El precio es muy competitivo.
Brad L.
2025-02-15 12:20:35
As described
Edson Guzman
2025-02-08 15:03:43
El producto llegó incompleto, no incluía los soportes aislantes y tornillería
Recommended Products

$4.99

$ 1 .99 $1.99

4.5
Select Option

$20.29

$ 8 .99 $8.99

4.9
Select Option