Jotta W2R-2P/3P/4P 100A 220V Mini ATS Automatic Transfer Switch 100 amp Electrical Selector Switches Dual Power Switch (3P 100A 220V)

Free shipping on orders over $29.99

$36.99

$ 18 .99 $18.99

In Stock

1.Color:4p 100a 220v


About this item

  • Operating Voltage:220V. Please ensure your home voltage is stable,because the working voltage can not lower than 190V,or the ATS will not work.
  • Working principle:when the main power off, it can automatic transfer to generator (generator should be on),when the main power is restored,it will transfer to main power
  • This Type ATS is for City Electricity or generator,please do not use an inverter as a backup power source.
  • This ATS is PC Type,which means It does not have overload and short circuit protection functions,its executive component is an isolation switch,its driving component is an electromagnetic coil, with fast transfer speed
  • Built with Arc extinguishing at the contacts.



Product Description

01
02
03
  • No,we can not use 110V to connect this ATS, we should use 220V and the voltage can not lower than 190V

  • PC : Power Contactor, PC Type ATS composed of coils and relays inside.

  • It has high tolerance and connection ability,much quicker transfer speed than CB type . but PC type ATS without overload or short circuit protection,you can equip a short circuit protection device according to your own needs.

  • No, this ATS can not be connected to a Photovoltaic Inverter,otherwire the ATS will be damaged.


JOSEPH P STRANEY
2025-08-14 18:50:19
I have the JOTTA JTQ3-100 here on my work table. It's the 3-line xfer sw. Says that 'control voltage' is 220 VAC but the conn drawing provided with the unit (and in the figures above on the amazon sales page) shows it wired for 110V operation. That is one side of the line goes to AR or BR, that's OK but the the AN and BN wires are tied to neutral, that is the center tap on the xfmr out on the pole. For 220V operation it should go to the other line, the other side of the xfmr not to the neutral line.I opened the unit up and applied 110VAC thru a diode bridge directly to either of the actuating coils inside (they main actuating coils want at least full-wave rectified AC) and it would reliably snap back and forth at 110VAC tho not as vigorously as at 220VAC.I note that there is a 220VAC (NNC68BP-4Z) coil relay in there wired to give the A connection preferential control over connecting its side to the load. This relay will not pull in on 110VAC so that's what makes it a 220VAC control unit.I'm saying the unit is indeed a 220VAC control unit, 220VAC is required to operate the unit, but the wiring diagram provided with the 220vac unit (and the diagrams on the sales page) shows it wired to operate from 110VAC. JOTTA must fix this diagram to show correct connection. It's confusing everyone who buys it!It's an excellent design, very safe, very fast, very reliable. Everyone who wants an ATS should get it. But JOTTA needs to fix their documentation!Correct me if I'm wrong.
VICTOR
2025-07-28 10:24:56
As described works great,it does the job
Suresh Khatry
2025-06-06 10:56:14
I installed this on Sunday. I was so happy that it worked flawlessly. When primary power failed, load was transferred to the backup power without a break in the supply. When primary power was switched back, the load was transferred seamlessly to the primary source. Then on Monday evening I noticed that the enrgized light on the backup side (green light) was not on. I thought the secondary power was off. But a check with the meter showed that there was secondary power. I then shifted to manual mode and switched source to secondary and power was still being delivered to the load. This showed that connections were good and backup power was good. Meaning the energizer circuit has conked off!! AT US $ 40 would expect a much more robust and long lasting device.I am updating this review because the mistake was mine. It's not meant to use inverter output as one of the inputs. It does state that in the description but since my inverter was a true sine wave inverter, I thought that would still work. I had written directly to the seller and they were extremely quick in their responses. After a few exchanges they quickly identified the cause of the failure and assured me of a full refund.The product does what its designed to do and has an extremely good transfer time. However, its not meant for inverter output.
Hope Lynea Green
2025-04-04 10:27:49
The unit is extremely simple. Mostly mechanical units on the inside. Couple diodes, plunger solenoids, switches and a couple LEDs.I hooked the unit up and it would default to the secondary powers side. Manually switching to the shore power side worked fine.When plugging into shore power, the device would hum. No smoke, nothing burned. Nothing had failed.When auto mode was enabled, the device would immediately switch to the secondary powers side and the only way to get it to go to the shore powers side was by manually cranking the knob to that side where it would start to hum.I beat my head against the problem for way to long. Decided to return as defective as another user left a review with the same exact issue that I had. Did a little more looking and found out there isn't enough power on a 110-120v system to trip the main relay to transfer the power to the shore power side of the unit. The hum was from the min relay not having enough power to activate to be able to switch the plunger solenoids.These units are cheap but built simply. I don't see how the device could be unsafe just because of how simple it is.Sadly, I am unable to find a 2 pole 110v switch like this so I ordered the 3 pole 110v version and found a 2 pole version on ebay for $24.48 including tax and shipping.I will be putting this in my camper to run the outlets of an inverter.Testing the device by manually turning the nob results in a huge clunk with zero, noticable, delay in power transfer.I'm not sure why there are so many 220v versions of this switch marketed to US users. Learn from my mistakes.
Wattman
2025-04-03 12:06:00
The media could not be loaded.
Jose
2025-01-28 11:41:56
Funciona sin problema, puede mejorar la calidad de los plasticos
Recommended Products

$149.00

$ 58 .99 $58.99

4.4
Select Option

$135.99

$ 65 .99 $65.99

4.9
Select Option

$379.00

$ 99 .00 $99.00

4.7
Select Option