Shopping Cart

Your cart is empty.

Your cart is empty.

Shars 0.008' Large Face Dial Test Indicator, .0001' Graduation, 1.5' Face Diameter 303-3210 P]

Free shipping on orders over $29.99

$60.95

$ 23 .99 $23.99

In Stock
  • SKU# 303-3210
  • Measuring Range: 0.008"
  • Graduation: 0..0001"
  • Dial Reading: 0-4-0
  • Product Included: 2 dovetail clamps 3/8" & 5/32"; Fitted case



Product Description

1

Shars Tool .008" Large Face Dial Test Indicator

  • Part# 303-3210
  • Measuring Range: 0.008"; Graduation: 0.0001"
  • Accuracy: 0.0001"; Dial Reading: 0-4-0
  • Measuring Force: 0.5N; Face Diameter: 1.5"
  • Contact Point Ball Diameter: 0.080"
  • Contact Point Length: 0.66"

Product Included

  • 2 dovetail clamps 3/8" & 5/32"
  • Fitted case

Product Spotlight

d

  • Large 1-1/2" white dial face with anti-glare finish.
  • Contact point with automatic reversal.
  • Steel Contact Mounted

F

  • Pivot point of the contact lever use miniature ball bearing construction to improve sensitivity and reliability.
  • 180 Swiveling and two directional functions.

x

  • Main body are made from high quality brass in satin chrome finish for long product life.
  • Dovetails top, front, and back mounting allows this indicator to be read in both horizontal and vertical position.
f

Closer Look

  • All pinions are mounted in an isolated assembly completely separate from outer body to maintain highest accuracies.
  • Crucial parts are made of special non-magnetic material to have high resistance to magnetism and yield high sensitivity.

Ghassan abuhamdeh
2025-08-24 14:59:11
This is a must have for any machinist. Accurate and big dial. Priced just right.
Mike from Pa
2025-06-08 10:42:29
Great indicator.Does what and indicator does.Repeats and has decent movement.
Barbara
2025-06-04 14:52:55
I bought mine from Shars. Black face. Been using it for about 2 years. Repeats well, better than expected, and adjusting its bezel isn't too crunchy. Good for static readings, which is how I use it. Dynamically, say, placed on a lathe, its response is slow compared to my better TDIs (Swiss B&S, Interapid, even a Mitutoyo). Hysteresis is not great. Noticeable. Its value depends on its application.
Nick
2025-06-03 14:32:18
These have a slightly larger face than other indicators. Good for readability, bad for tight spaces?Shars is China, but so-called "premium China". This is not a bad product for the price if you don't demand USA- or Japan-made.
Rose 666
2025-05-24 18:01:14
The dial is easier to read, the scale action is smooth and consistent. I haven't had any issues keeping tolerance or zeroing in parts with this so as far as I'm concerned it's a no-brainer for this price.
John V.
2025-01-07 15:00:59
Haven’t used extensively but seems like good quality
Steve
2025-01-06 14:17:49
The needle will not move smoothly, it jumps 5 or 6 increments at a time. Not even close to a Brown & Sharp. I've had other Shears products and found them to be very reliable but this one is of no value as a .0001" indicator.
Gearhead
2024-12-29 16:52:43
Second Shars gauge unit: This is our 2nd such instrument received after returning the 1st unit.Amazon score = 3 stars; better, but still has quality/functional issues.Shars 0.0001" incremented horizontal dial indicator is acceptable but with limitations. Needle/dial readings are accurate within approx. 0.00005" when moving the probe towards the plane of the dial/face, which at first appears to be very good. However, when moving the probe in its other/opposite direction (i.e. away from dial/face plane), the needle stutters/jumps in the dial region of 0.00065"-to-0.00075" (i.e. at about 3/4 sweep, analogous to 8:30-11:30 on a clock dial). The Shars cannot be trusted for accuracy in this range. So, it is acceptable with limits, considering its value price, but realize that this particular unit does have a blackout/unusable zone for some of its measurement range.Our first Shars gauge summary: Amazon score = 1 star. unacceptable/rejected.Could not perform measurements. Needle very erratic: jumps and stutters when attempting measurements. The first Shars 0.0001" incremented horizontal dial indicator was rejected and returned to Amazon for refund/exchange.Acceptance tests were performed using NIST calibrated digital mic (10X greater precision level Mitutoyo) and metrology table.