Shopping Cart

Your cart is empty.

Your cart is empty.

testo 310 I Residential Combustion Analyzer Kit I Flue Gas Detector Set for Heating Systems

Free shipping on orders over $29.99

$578.00

$ 99 .00 $99.00

In Stock

1.:App Connection


2.Size:Standard Set


About this item

  • EFFICIENT; The testo 310 co2 detector is ideal for more complex flue gas analyses, maintenance, safety checks, and furnace efficiency confirmations of residential heating systems
  • VERSATILE; With its advanced sensor technology, the carbon monoxide meter offers accurate readings of O2, CO2, ambient CO, draft and pressure, temperature and combustion efficiency
  • DURABLE; Thanks to its rugged housing with an integrated, kink-resistant hose, the gas leak detector is securely protected from impact and leaks
  • EASY OPERATION; Equipped with a backlit display, quick-start and integrated condensation tap and magnet, the co2 monitor delivers a hands-free and easy application
  • COMPLETE SET; Includes a probe with cone, extra hoses and particulate filters as well as a pressure plug and a protective hard-shell case


Setting a new standard in reliable combustion tuning - the testo 310
Get your readings right - every time: The testo 310 provides accurate measurements for O2, CO (with built-in NOx filter), CO2, undiluted CO (CO air free), ambient CO, draft & pressure, temperature (flue & ambient) and excess air for applications like checking boiler efficiency, tuning and water heat checks.
Technical Data:
Temperature measuring range(K TC): -4° to 212 °F / -20 to +100 °C
Temperature measurement accuracy: ±2 °F / ±1 °C
Temperature measuring range (J TC): 32° to 752 °F / 0 to +400 °C
Temperature measurement accuracy: ±1.8 °F (32° to 212 °F) / ±1 °C (0 to +100 °C); ±1.5 % of mv (> 212 °F) / ±1.5 % of mv (> 100 °C)
O2 measuring range: 0 to 21 Vol.%
O2 measurement accuracy: ±0.2 Vol.%
Draft measuring range: -8 to +8 InH₂O / -20 to +20 hPa
Draft measurement accuracy: ±0.01 InH₂O (-1.20 to +1.20 InH₂O) / ±0.03 hPa (-3.00 to +3.00 hPa) / ±1.5 % of mv (Remaining Range)
Efficiency measuring range (calculated): 0 to 120 %
Flue Gas loss measuring range: 0 to 99.9 %
CO2 calculation measuring range: 0 to CO₂ max (Display range)
CO2 calculation accuracy: ±0.2 Vol.%
Pressure measuring range: -16 to +16 InH₂O / -40 to +40 hPa
Pressure measurement accuracy: ±0.2 InH₂O / ±0.5 hPa
CO and ambient CO measuring range: 0 to 4000 ppm
CO ambient CO measurement accuracy: ±20 ppm (0 to 400 ppm) /±5 % of mv (401 to 2000 ppm) /±10 % of mv (2001 to 4000 ppm)
Dimensions: 8 x 3 x 2 in. / 201 x 83 x 44 mm
Weight: (with probe) Approx. 25 oz. / (with probe) Approx. 700 g
Scope of Delivery:
✓ testo 310 combustion analyzer
✓ sensors
✓ probe with cone
✓ hose
✓ silicon tubing (for pressure)
✓ 5 x particulate filters
✓ 5 x pressure plugs
✓ calibration certificate
✓ Hard-shell case


Bud
2025-08-28 12:07:12
Solid,reliable,and affordable compared to others
Customer
2025-08-26 12:57:58
Works great. Had to buy the printer separate because they were out of kits. Maybe splurge and buy the one compatible with the app though
Brian
2025-08-25 15:26:35
Fast, accurate and well priced! The tester works great and was easy to figure out. The instructions were a little cryptic but once you start using it I was able to figure it out just fine. The magnet is a good strong neodymium. The printer works great with dates and times and space for contractor name and number write in. I am mostly using it for condensing boilers and water heaters. No it's not the super high end testers with the additional Sci readings but it will work for 95% of what I do need it for.
Dale Gianforte
2025-08-14 13:46:12
Top notch equipment at the lowest price.
Keith
2025-08-13 10:05:09
Received the Testo 310 Analyzer Kit on 1/18/25. Went through the manual and watched a couple of YouTube videos which were very helpful. Then the 310 Analyzer started taking 4 calibration cycles ending with an error code of E06 which means Sensor will be soon worn out > Contact Tesco Service. Should not have this issue with a new 310 Analyzer Kit. Emailed technical support on 1/22/25 and it is now 1/26/25 and have not received any response. Question the quality of the 310 Analyzer Kit and definingly the technical support which obviously has nowhere to be found. Will be returning the 310 Analyzer Kit.
August
2025-07-05 13:20:37
Works well for residential systems, able to quickly tune furnaces and boilers for optimal AFUE. I routinely get 83-86% out of standard 80% furnaces after using this tool. Make sure you know what values to look for when balancing a system, such as excess air percentages and O2/CO2/CO levels, etc. Nice to be able to take static pressures on duct work as well as temperature splits, although the temperature readings take a while to even out. Easy to use, easy to switch from propane to nat gas, only gripe is that it didn't come with the printer. Do yourself a favor and buy the kit that includes the printer. Easy to prove your readings instead of writing down values on your invoices.
John Buser
2025-06-04 10:42:03
Easy to use.... but $$$. But sometimes you have no choice. I got this because I was having serious problems with my Gas Furnace and after 3 attempts with professionals ($$$$$) fiddling with the Gas Control without testing the exhaust, I ordered the the Analyzer. It took me roughly 10 Minutes to read the Manual and another 10 to set the combustion correctly.Great product...
Michelle Murphy
2025-05-04 14:24:57
Was deceived by photos of a hard strong case not this flimsy crap case. Very disappointed
Carlos garcia
2025-04-15 15:33:10
Nunca leyó las ppm una lastima..Se tuvo que devolver..
GF
2025-02-27 12:20:34
Came with 10 months on the calibration certificate. Definitely a brand new never opened unit. Very happy with my purchase
Alan casey
2024-12-10 12:14:38
Good unit, easy to work with
antofox
2024-11-26 16:07:06
Très bon rapport qualité prix.Je m'en sert pour faire les réglages brûleur.
Recommended Products