Shopping Cart

Your cart is empty.

Your cart is empty.

VFD 7.5KW 10HP 220V 1 or 3 Phase Input 3 Phase 0-400HZ Output 50A Variable Frequency Drive Controller Vector Control Inverter Converter for CNC Motor Speed Control and Spindle

Free shipping on orders over $29.99

$234.99

$ 99 .00 $99.00

In Stock

1.Style:0.75kw (1hp 220v)


About this item

  • 【Attention】External resistance is not supported, you can adjust the parameters to achieve the function of external resistor. If your motor is heavy duty, please choose a higher power VFD. △ (Delta) connection is recommended for this product. If you have complex needs, please do contact customer service before use to get accurate advice. Please attach pictures of the load equipment parameters ( e.g. nameplate of the motor).
  • 【Product Parameters】Power: 7.5KW, input voltage: AC 220V(180-250V),output voltage 220V;input current 35A, output current 50A; input frequency 40-60HZ, output frequency: 0-400HZ; input phase: single-phase or three-phase, output phase: three-phase.
  • 【Intuitive Display and Button】The display and keys of the product can let users get started quickly. After the panel is disassembled, it can be connected to the corresponding interface to achieve remote control.
  • 【Various Protection】The product has overload protection, fuse protection, overvoltage protection (DC voltage > 400), or low voltage protection (DC voltage < 200), restart protection, stall protection, short circuit protection, and overheat protection.
  • 【Good Noise Control】The product has the advantages of low noise and low electromagnetic interference, which are achieved by the excellent PMW control technology and component compatibility design. There is enough space for cooling between each component, and the product casing is designed with multiple holes, the above features can make this VFD have a longer service life.



Product Description

IMPORTANT NOTE

  • This drive only works with 3-phase asynchronous motors. Please make sure your motor is a 3-phase asynchronous motor before purchasing. To protect the VFD, be sure to press the red button "Stop" and turn off the power when you stop using it.When the VFD is working, the inside of the heat sink may reach about 176℉ (80℃), please pay attention to the protection measures!
  • The motor ( or other loads ) and the VFD can only be connected by wire without anything between (eg. No switch can be installed between them).If you want to use the switch to control the load, please refer to the following method to connect the terminals. The two ends of the switch are connected to FWD and GND, turn on the switch, the motor is turning positive, turn off the switch, the motor stops working.The two ends of the switch are connected to REV and GND, turn on the switch, the motor reverses, turn off the switch the motor stops working.Select the function you want to achieve to connect the switch.

Panel Operation Instructions

VFD

Advanced Features

  • Independent control panel and detachable for remote control.
  • Parameters can be set to achieve the braking function.
  • Support 5V or 10V PWM control frequency.
  • Single/Three-phase: We offer single-phase 220V and three-phase 220V inputs. When used for single-phase, the other phase can be used as a spare line.
  • Use the parameter setting to achieve the effect similar to the external resistor.
  • A high capacitance with low output torque 0.5HZ-150% and low speed operation.
  • Superior anti-interference performance.
4

Simple operating guide(motor)

Connecting load devices (eg.motor)

  • If the input power is single-phase 220v, then connect to R and T. S is empty and does not need to be connected;
  • If the input power is three phase 220v then connect to R, S and T;For 3KW power models, only L and N need to be connected and the other wire is empty.
  • The three wires of the motor are connected to U,V,W, Motor junction box needs to be changed to Δ wiring method (You can see the motor nameplate is generally marked delta for three-phase 220v, Y for three-phase 380v, if you do not understand the motor name plate to take photos to us).

Set The Initial Test Parameters:

  • pn32=6, pn02=rated frequency of the motor, pn03=2, pn04=1;pn10=rated frequency of the motor;pn12=rated frequency of the motor
  • After setting as above, press the RUN button to start and STOP button to stop, FWD/REV button to switch forward and reverse, and the panel up / down buttons to adjust the speed.

VFD 110V

Cooling Fan

With fan cooling and efficient heat dissipation capability, it makes sure the internal temperature of VFD is suitable for long and consistent operation.

VFD Board

Excellent Material

The drive board is cleaned and spray painted. A high torque, high precision, fully adjustable speed drive with unique control method enables it to adapt to harsh grid, temperature, humidity and dust interference capability.(Protection class IP30)

VFD 220V 7.5kw

Widely Applications

Used in mechanical winders, mixers, extruders, slitters, winders, compressors, ventilators, pumps, grinders, elevators, and other speed control machines.


Randy
2025-08-23 14:03:56
It works fine but the instructions for the settings are unclear
Jason
2025-08-21 17:16:21
I bought two of these. Hook them up to my lathe and bridge port mill and works amazing.
John Kennedy
2025-08-14 14:49:05
I bought this VFD to replace the Westinghouse/TECO N3 VFD which failed on my 2HP Bridgeport milling machine. I think the unit is actually the ISACON A2 Series, I'm not sure if HKS rebrands it or if HKS is part of ISACON? This unit is considerably smaller than the TECO N3 and only has 2 mounting holes. There is no strain relief for the AC line input wires nor the motor output wires. I used the strain relief bracket off of the TECO, but this still leaves the wires exposed. I took off one star for no strain relief. I'd also prefer it if all the wires were completely enclosed. With the wires exposed, I'm not sure if this unit meets US UL wiring code or not? The terminals for the AC line input and motor output are also quite small, I used forked terminals for a US #6 stud (or you could use whatever the metric equivalent is), this means you'll probably have to use #12 GA wire or less. I followed the instructions given in the "Set The Initial Test Parameters" found on the Amazon page for this unit, I just changed the PN02, PN10, and PN12 parameters to 60Hz instead of 50Hz (I'm in the USA). The instruction manual is very brief but adequate for what I needed, but could be better explaining some of the more advanced features. The turn on and turn off acceleration default to 10S and are much slower than the TECO unit, but these can be easily changed with PN08 and PN09. I used an external pot on the TECO N3 to change the frequency and thus the motor speed, but this can be done on this unit with the UP/DOWN buttons on the front panel, which is nice feature. You can also set it up to use an external pot if you want to. Initially I like the way the unit works, the front panel seems fairly intuitive, and everything worked as I expected. The price is certainly appealing, much cheaper compared to something like the TECO. It will be interesting to see how it holds up in the long term, but I would certainly recommend it at this point especially for a home machinist such as myself.
Danno the Unfortunate
2025-06-05 11:45:11
got the 5hp unit to run my 3ph 5hp compressor since my home shop doesn't have 3ph. manual is terrible but there are so few settings its not too bad to figure out, however once the belts were tight it started immediatly over currenting trying to run my load. even with loose slipping belts it was extreemly sensitive to the settings on the unit to run it even at lower power.
JMGriffith
2025-04-02 13:44:50
The media could not be loaded.
Charles R Takach
2025-02-23 15:39:31
It works as it should
Doug Busch
2024-12-18 14:39:37
I have purchased two of these units, for different machines. Both VFDs exhibit the same issue. The acceleration parameter works when the unit is set for panel control, but when set for start/stop by external switch closure, acceleration time is ignored, leading to an instantaneous start and overcurrent error when starting. (BTW, I've set up many VFDs, this is not an operator error). There is no tech support available. This severely limits how the unit can be installed and used. I will not buy from this manufacturer again.
Customer
2024-11-14 20:17:10
It works great.
Recommended Products