About this item

  • Easily replace hardwired Firex smoke alarms with First Alert or BRK smoke alarms
  • Ideal for retrofitting jobs, Package dimensions 1.85 x 8.39 x 5.24 inches, individual unit dimensions are 3 x 1 x 1 inches
  • Compatible with SC9120B, 4120-series, 9120-series, 7010-series, 5919, 2002RAC, SC6120B, HD6135FB, and RM3 First Alert or BRK alarms
  • Compatible with 406 (G-6), 4518 (ADC), 4618 (FADC), 484 (PG-40), 4480 (PAD), 5700 (ADH), and 499 Firex alarms
  • Includes 12 smoke alarm adapter plugs.Refer to the PDF attached below in Technical Specification for User Manual for compatible models and brands


First Alert ADF-12 BRK/Fire Smoke Alarm Adapter Plugs take the hassle out of replacing 120-volt hardwired Fire smoke alarms that are outdated or expired. Ideal for retrofitting, these convenient smoke alarm adapter plugs eliminate the need for rewiring when replacing an existing Fire detector with a BRK or First Alert alarm. Simply insert the three-pin male connector into your existing Fire ceiling plug, insert the female connector into your First Alert or BRK smoke alarm, and secure the smoke alarm into place. Compatible with a wide range of hardwired First Alert, BRK, and Fire smoke alarms, these adapter plugs can help you save time and installation costs when you're updating the fire safety system of your home or facility. The package includes 12 adapters--enough to install 12 smoke detectors. Package dimensions 1.85 x 8.39 x 5.24 inches, individual unit dimensions are 3 x 1 x 1 inches


Good&Bad
2025-09-03 10:55:47
These worked perfect! I replaced our original builder interconnected 18 year old FireX 120-1182 Ionization (Flame) Fire Detectors with BRK/First Alert 7010B (Photoelectric Smoke) Detectors. The thought of rewiring each detector in the ceilings was more than unpleasant since I am still recovering from hip replacement surgery and teetering on a step ladder made me very uneasy. I saw these on Amazon, read numerous reviews (thank you everyone) and decided to try them. They worked great! After replacing all the units, I had the conversion time down to 5 minutes each (Hint:Using an inexpensive power screwdriver definitely helped working overhead!).First: I removed the 9V Eveready Heavy Duty Non-Alkaline batteries that came inside each detector and replaced them with a new 9V Alkaline battery (probably not necessary...just a personal thing), I then 'push tested' each before climbing the ladder to install the new wiring adaptor (why put up a detector that may be a factory dud?).After finishing all the replacements, just to make sure both the 'interconnectivity and the smoke detection alarm really worked in a real life situation', I lit a paper fire in a pail (in a safe non-flammable area), then put it out after it got going strong so it would smoke a lot, then held it about 12" below the detector. GREAT! All our new alarms went off at virtually the same time. So now I'm confident my family is safe in a real life situation and not just relying on a simple 'push' alarm test to hear a beep! Additional Note....I then also installed (6) BRK/First Alert Battery 'Family Gard' Model FG200 Ionization (Flame) Detectors as I felt we should have two different types of detection for safety. I bought three 2-Packs of these @ $10 ($5+- each). Well worth buying and in my own separate 'real life test' with real flames this time, these flame detector alarms worked, though only where a flame was present (they are not interconnected!). Because the Family Gard units are battery powered with no wiring required, I was able to install each in the same time of just a few minutes ~ with a power screwdriver :). Please think about adding additional safety for such a low cost. (Ionization + Photoelectric). Just my own opinion....The installation of the new wiring adaptor was simple 'if you have strong' fingers.The new connector snaps onto the existing FireX 3-pin connector (at least on ours it had to) in order to secure itself and not pull loose. If you can't snap it together, you may be able to use a pair of pliers and slowly & carefully pinch the two connectors together working each side down a little at a time so you don't end up snapping or breaking the existing connector, until they snap together...If you break the existing connector or one of the three small pins, you will have to remove the existing connector and install the new hard-wired connector.The only other issue I ran into was pushing the new connector and additional wiring back up inside our already crowded ceiling box took a few different tries until a decent fit worked.Take your time here, I WOULD RECOMMEND DOING THIS BEFORE ATTACHING THE NEW DETECTOR TO THE NEW WIRE ADAPTORS. It's so much easier to deal with stubborn wiring in a crowded space without also having the new detector dangling below, hanging on the wires. If the new connector doesn't fit easily into the existing ceiling electrical box (it probably won't unless you're lucky), look at the wiring inside the ceiling box & try to find a relatively uncrowded area where the new connector will fit into, once you find or create that area, the new connector & short wiring should be able to be 'gently' pushed inside..don't break wiring connections!. Then go ahead and install the new connector wiring to the Detector. if the wires come out of the ceiling again while doing this, now, since you know how you're going to put everything back into the ceiling box (because of your trial run), just place it all back inside the ceiling exactly where you had it....Having to buy 12 connectors at a time is quite an oversell, if I needed 8,9 or 10, then I would be fine with purchasing (2) 6-packs, but when a home has 6 or less, it really is an oversell. However having said that, I wouldn't hesitate to buy them again knowing now how simple it made the conversion from FireX to First Alert!NOTE: We are Amazon Prime members and I can say we absolutely did not receive any consideration, nor were we asked whatsoever for our comments here. Life is much too important for anyone to play games with. We purchased the wiring adapters from Amazon, but just to be fair to Amazon, we purchased the detectors mentioned above elsewhere. But again, to be fair, if we had not seen a super-sale within a couple of miles from home for these detectors, we would have gladly ordered and depended reliably on Amazon to deliver us these detectors within 2-days and to back us up if something was wrong!
Kevin S. Merritt
2025-05-29 18:16:11
Replaced the smoke alarms in mom's house, but they used a different connector. Rather than rip everything out of the ceiling, I found these adapters to connect new units to older connectors. Saved me some time and effort. Worked great!
James Ettwein
2025-05-15 18:15:38
Easy to use. Effortless plug-in to mount your new detector, in spite of the old brand.
Customer
2025-05-12 12:04:42
I converted 4 Firex Smoke and combo Smoke/CO to First Alert/BRK. These Cables made it extremely easy! The cables snapped together and fit without issues.
Joyce G
2025-04-13 14:59:27
As most products go things change over the years and trying to rewire something to handle the new version is a nightmare. But THESE made it SO EASY. Just snap these adapters in place and put up the new verson.
C. Vero
2025-04-01 15:54:29
I usually do not write reviews but what a piece of junk. I bought these from a warehouse deal and they were cheap so I figured why not, maybe same some time. Half were missing which is an Amazon warehouse issue, but otherwise the product is a very poor way of doing the job. I knew this and knew I should have never bought these.Just use the connectors that come with the new detectors, strip off some extra insulation to expose about 1" of new wire, turn off the circuit and wire these in the proper way.Whoever installed your original connectors may have used the wrong size wire nuts, now is a good time to put the proper size on as needed. This literally takes about an extra 3 minutes per detector to hard wire in the new ones and you can be sure to get a good strong mechanical seal (twist). All nice and secure and done the proper way.Another really good reason to skip this product, the old pigtails that these are supposed to plug into are old and brittle. The Romex in the ceiling is just fine (not stranded wire and good insulation) but if your old detectors are old enough to need to be replaced, the wire is probably ready too. Will the old wire work? Sure, but it probably crusty and you are cramming it into the J box with new extra length of wire.Do you want it done fast or do you want it done right? Avoid this product and spend the extra 3 minutes per detector to do the job correctly. You will be glad that you did.
Michael G.
2025-02-12 13:21:42
Replaced my way overdue FireX smoke detectors with First Alert BRK 3120B models. These adapters saved me the hassle of needing to rewire every unit. They clicked in place firmly, and with a little jossling I was able to fit the extra wiring of the adapter up into the junction box with all of the existing wiring. Replaced four smoke detectors in under ten minutes. Everything works. I'm happy.
Philip M. Vo
2025-01-29 18:34:17
It was barely fitted in with the tape hold around both connectors from the alarm.