Shopping Cart

Your cart is empty.

Your cart is empty.

MENSI Propane Natural Gas Fireplace, Deep Fryer, Furnace, Water Heater Parts Pilot Burner Assembly Replacement 750 Millivolt Thermopile Generators Q313A (24' Glass Fiber Wire)

Free shipping on orders over $29.99

$12.99

$ 5 .99 $5.99

In Stock
  • The Thermopile is a Replacement of Fireplace Pilot Burner Assemnly Parts with Internal resistance (25°C) around 4000 mΩ and heating voltage above 750mV normally installed on plilot assembly used for fireplaces, frying, heating appliance, Normally installed on the pilot burner assembly, Assembly Replaces 10002265 10002264,25660 | 4021-732,69L17,446-510A,108084-03,69L17 Etc
  • It will needs about 60 seconds (2 minutes ) to heat up to the 750mV and the flame should be heat the middle of the head sensor, So you may need time to waiting the valve start work. CSA certified, certification No.: 80133821,Master Contract: 604329, Suitable for The Fireplace Pilot Burner Model No.: Fits For 10002264,10002265 HHT Majestic & VC Pilot, 108084-01,-02-03,69L18 Pilot Assembly for IHP Lennox Direct Vent Fireplaces, Fits for Deep Fryer 3WSPAF-A Etc , Common Thermopile use for Fireplace, Deep Fryer, and Commercial Cooking Range.
  • Normal working temperature 700-750°C. Replacement of Heatilator Heat n Glo 24" Lead Thermopile, Fits Empire DV210, DV215, GWT25, GWT35, and GWT50 Models Replacement of PITCO 60125501 Model
  • The Repalcement of heatilator thermopile 100% Tested, Quality Assured. Suitable For American Deep Fryer Thermostat Control Valve Pilots Light
  • Most Common Application Pilot Flame Model: Cecilware Fryer, Imperial Fryer 3WSPAF-A, Fireplace 10002264, 10002265, 4021-732,69L17,J4117,108084-02,4021-736,4021-737,LPG8404 14D0477, PP225, 25660 ETC for for HHT, Majestic, Monessen, Temco, and Vermont, For Catering Fryer, Fireplace, and Water Heater Pilots.



Product Description

thermopile

Specifications:

  1. Lengths: 24/36 inches
  2. Wire Material: glass fiber wrapping line, metal aluminum wrapping Line
  3. Connecting type: spiral type and two-pole plug-in type Working temperature:700-750°C.
  4. 750mv Thermocouples have long been used in self-powered heaters,deep fryer and hot water equipment. It has been proven in millions of appliances as the contractor's preferred thermopile and are found in many of today's gas fireplaces. The Thermocouple is suitable for the following models product. You can take it for reference.
  5. For Models: QV32 QV32-A QV32B QV32B-A (Pre Serial # 0021080519) QV36 QV36-A QV36B-A (Pre Serial # 0021076968) QV36D QV36D-A QV36DB QV36DB-A QVI25 QVI30 QVI35 QVI-25FB QVI-30FB QV Pier Heat N Glo Gas Stoves: AT-Grand (Also fits the B, C and D models) AT-Insert AT-Supreme (Also fits the B, C and D models) AT-ZC and AT-ZC-B Bay Insert and Bay Insert NS CFX Grand-B CFX-IN-B FB-Grand FB-IN FB-ZC Grand-I35-SP Grand-XT Supreme-I30-SP Supreme-XT ZC-XT Bay-38HV Bayfyre-TRS Bay-GDV-95 - After May 1996 L-COR-TR L-COR-TRC L-COR-IPI Pier-38HV Pier-TR Pier-TRC Pier-TVFL R-COR-TR R-COR-TRC R-COR-TRC-IPI ST-38HV ST-42TVFL ST-TR ST-TRC 6000BE 6000Camp 6000DVTFL - After serial # 12614 6000FLS 6000G 6000GBV 6000GDVFL - After date code 2/96 (Only for 30 sec pilot assembly) 6000SEB 6000TRB 6000TRI 6000TRI-SP 6000TR-NF 6000TR-OAK 6000TRXI 6000TVB 6000TV-OAK 6000XL 6000XLS 6000XLS-NF 6000XLSB 6000XLT 6000XLT-NF 6000XLTB 7000TR-NF 7000TV-NF 7000XLS-NF 7000XLT-NF 8000C & 8000C-LP 8000DVTFL - After date code 2/96 8000GDVFL - After date code 2/96 8000TR 8000TRC 8000TRD 8000TR-Oak - Pre serial # 0021116425 8000TVC 8000TVD 8000TV-Oak - Pre serial # 0021116948 BE-41 BE-41B BE-41B-IPI
  6. Replace the Thermopile or Robertshaw Model,s Emerson Models, Pitco Models Etc
24" Thermopile Fireplace

24" and 36" Thermopile Replacement for Fireplace

Length 24" and 36".

Amored and non Amored.

Suitable for Gas Fireplace install on Pilot Light Flame.

At least 750mV to Open the Thermostat Valve

Application: Fireplace, Heater, Fryer, Commercial Kitchen.


Alan
2025-09-01 10:19:26
Perfect fit for my Kozy Heat (Hussong) 761DV gas fireplace. Wall switch had ceased functioning. Thermopile tested low on MV output. After replacement, Voile! wall switch functioning again. Total time to replace: 1 hour with most of the time spent removing and then reinstalling the fireplace glass and logs. No idea on longevity of this replacement (original lasted 20+ years).
Captain Reviewer
2025-08-26 12:16:20
Lifesaver. Watched some Youtube videos and troubleshot my Cozy brand wall heater and determined that it was the Thermopile. I can't remember exactly, but I think the pilot light would stay on but the heater would not start. My old one was just under 230 millivolts or something which should have worked but I guess these are sensitive. It just worked. Plug and play. Phew. In a pinch you can try cleaning the old one with a dollar bill (anything coarser will remove the metal coating I guess?)
Camille T
2025-08-25 13:51:45
Exactly what I needed to fix a pilot that would not stay lit. Replaced 26 year old thermopile in Marco (discontinued manufacturer) fireplace. No original parts available. I did have to splice connector from the old thermopile but easy and just used some butt connectors. Work was a little tedious as fireplaces don't have a lot of room to work. But about an hour later all was running. Took millivolt measurements when done and all well within spec. Saved me a bunch of money by not having to get a service call or buy part at a local overpriced fireplace store.
mterick
2025-08-22 17:59:31
Value priced, and when the thermothingy heated up the current was enough to wake up the electromagnet in my old gas fireplace. I heard it open, strong! Fixed my fireplace, I'd buy it again.
Craig Roberts
2025-07-06 15:35:28
Works and no problems
Fuji Nguyen
2025-06-30 13:48:25
After replacement the fire stayed on. You can DIY, est 1 hr.
Hyong Kim
2025-06-10 15:53:40
I love the price.It works good so far
CAN
2025-05-16 12:28:40
This thermopile is advertised and specified to produce 750 mV. My unit only produces a maximum of 575 mV.I tested it open circuit (under no load) with my stovetop flame fully engulfing the upper sensitive portion of the unit (much more flame than normally realized from the pilot light) so that the upper portion of the unit was glowing red hot. After about two minutes, the open circuit finally crept up to 575 mV, but would go no higher. I went ahead and installed it until I can get a fully working replacement, and it only intermittently operates the gas valve in my fireplace.FWIW, I have degrees in both Physics and Electrical Engineering, so there is a reasonable chance I know what I'm talking about when I say that the product I received is out of spec, and not by just a little. I won't be buying any MENSI product again, if I can avoid it.
jimmy smits
2025-04-25 10:55:28
I ordered this product online when i figured out that it was the problem with my gas fireplace. would not stay lit and would not fire up. Received very quickly in perfect condition, I installed it in about 30 minutes and fireplace fired up immediately and is still working great after a month or so. this product was a perfect replacement for the OEM. I saw a few competing products online and they were less money but I decided on this one even though it was a little higher price. it seemed to be the best quality and it is working great.
Fiddy
2025-04-24 10:49:05
Got two. One for the downstairs fireplace and one spare for when the upstairs one needs replacing. Pain to install but that's the fireplace's fault, not the thermistor.Original ran for 16years. This one is on it's second year. No issue.
Customer
2025-03-20 10:19:39
Install may be tricky for some , but the product is working fine .
Mike Morneau
2025-02-14 11:22:09
Installation of a thermopile is not for everyone. There are lots of YouTube videos available that show you the replacement procedure, and also check out the YT videos on how to test your existing thermopile before ordering a new one. This one was an exact replacement for the old Honeywell it replaced. Just be sure to order the correct model for your needs, and also pay attention to the wire/cable length
Adminitor
2025-01-30 18:15:40
Does not work. Looks the same as original but did not work.