They work great! I'm so glad I tried them out. Not to say it may not fail, because I'm using it on an AC volt circuit between an AC (power pack) transformer and the track for O Gauge trains. Post war locomotives, and modern locomotives. Before I put the circuit breaker in place, if a Caboose malfunctioned (shorted out) at a switch track the wiring for the light inside the Caboose would melt big time! Because the post war (power pack) transformer has a 20 AMP breaker built in it. That's why I put the 5 AMP in-between the track and (power pack) transformer. Believe me, I thought once I put the 5 AMP breaker in, there would be no eras on the tracks. WRONG! So far the breaker saved the wiring about ten times. So it does work more than once.
Zacmanrules5
2025-07-05 20:18:09
I wired it in with the track for my train table and it works great! Trips before I even realize the train derails! WILL BUY AGAIN!
Againstallodds Art Barrera
2025-05-09 18:00:41
Great parts. I use them for my training classes
R&P
2025-04-09 17:21:03
Considering the price, this is a good value. Just understand, the accuracy of the current ratings is way off. The trip current/time to trip is quite consistent tho, so knowing this ahead of time, you can plan your circuit accordingly, and expect reliable operation.I tested these with a "Kill-A-Watt" meter using various resistive loads at 120VAC. Some of my results:3 Amp Breaker: Load 4A = no trip; 4.8A = Trip in 2 min; 5.9A = trip in 15 sec; 7.5A = trip in 5 sec.5 Amp Breaker: Load 8.2A = no trip; 9.3A = trip in 1 min; 10.9A = trip in 10 sec10 Amp Breaker: Load 14.4 = no trip; 14.9A = trip in 1.5 min.I didn't test above 15 Amps load, but can assume the 15A Breaker will perform similarly, and trip around 19 Amps. Again, if you know these limitations beforehand, and plan accordingly, you'll be fine.
bcad
2025-03-14 11:45:31
Does not look very solid but does the trick!
ken kushner
2025-02-11 15:45:37
Pricing was great
guy
2025-01-26 12:51:44
Fonctionne très bien mais j’en ai commandé 5 toute reçu mais aucun bottons de protection dans la boîte ni de nut pour le sécuriser sur le panneau de contrôle
Renald evers
2025-01-19 11:51:14
Parfait pour mes besoin merciBon services
Recommended Products